Zirconia Oxygen Analyzer
  • Zirconia Oxygen Analyzer
  • Zirconia Oxygen Analyzer
  • Zirconia Oxygen Analyzer

Zirconia Oxygen Analyzer

Separate type zirconia oxygen analyzer/probe latest oxygen analyzer used in furnace and bolier

JZY-II series intelligent zirconia oxygen analyzer is a practical and reliable automatic analytical instrument. It can cooperate with various electric unit meters, conventional display recording instruments and DCS distributed control system to quickly and correctly detect and analyze the flue gas content generated by combustion equipment such as boilers, kiln and heating furnaces. . To achieve low-oxygen combustion control, to achieve energy-saving purposes, reduce environmental pollution.

Zirconia Oxygen Analyzer

Separate type zirconia oxygen analyzer/probe latest oxygen analyzer used in furnace and bolier


JZY-II series intelligent zirconia oxygen analyzer is a practical and reliable automatic analytical instrument. It can cooperate with various electric unit meters, conventional display recording instruments and DCS distributed control system to quickly and correctly detect and analyze the flue gas content generated by combustion equipment such as boilers, kiln and heating furnaces. . To achieve low-oxygen combustion control, to achieve energy-saving purposes, reduce environmental pollution.

JZY-II series intelligent zirconia oxygen analyzer has two parts: JZY type zirconia probe (primary instrument) and JZY oxygen quantity transmitter (secondary instrument).


021.jpg


Parameter function
Loc: To set the following parameters, first set Loc to 808. After the setting is finished, set Loc to other values to prevent misoperation and change the setting value.
dA: equal to zero current output is 0~10mA, not equal to zero current output is 4~20mA
SC: the unit for the oxygen potential migration of the sensor is mV
dIL: 0  +20.00, linear input zero display value
dIH: 0 — +20.00, linear input full scale display value
Corresponding to dIL~dIH, 7 and 8 pin output current 4~20mA
CC: Heating temperature setting value, when the temperature reaches the set value, the meter automatically stops heating and maintains this temperature.